Request a quotation

Plywood for shop walls works best as a specified interior lining, with a sanded decorative or paint-ready face and a core chosen for the fixing layout. Shop counters and display units need their own thickness, finish and edge details. Fire performance belongs to the tested wall or fixture assembly, not a timber species name.

Cover graphic: Plywood for Shop Walls: Retail Fit-Out Panel Guide, 3–40 mm
Plywood face and edge selection for shop walls, counters and display fixtures.

Which plywood for shop walls gives a clean retail finish?

Sanded furniture-grade plywood with a consistent face veneer is the starting choice for dry shop walls. Select a paint-ready face for opaque colour, a decorative veneer for exposed timber, or a factory-faced surface where the finish schedule calls for melamine or high-pressure laminate (HPL). A plywood shop wall is a system of panels, joints, supporting rails and fixings, rather than a sheet selected by thickness alone.

Retail lighting makes surface defects conspicuous. A raking spotlight can reveal a shallow sanding ridge that disappears under ordinary workshop lighting. Inspect the sample vertically under the intended light colour and angle, not merely flat on a bench. For a long wall, set the grain direction before cutting; changing it midway can make otherwise matching sheets look unrelated. If the wall is painted, use the same primer and coating sequence on the approval sample that the installer will use on site.

The core is equally important, although customers never see it. Tight, well-joined inner veneers give a more dependable edge when a shelf bracket or display rail is fixed near a cut. A loose interior core can reveal gaps when an opening is routed. The plywood for interior projects comparison helps distinguish appearance-led panels from general-purpose commercial stock. A wall with heavy suspended merchandise also needs an engineered fixing layout that transfers the load to the supporting structure.

A practical wall schedule identifies the visible face, panel orientation, joint treatment, fixing pattern and finish. It also identifies service openings before panels reach the site. Where the designer wants an uninterrupted wall, joints can align with shelving uprights or decorative reveals. Where panels are deliberately expressed, consistent spacing matters more than hiding every joint. Order the face sample with the proposed joint detail so the buyer can judge the whole effect.

A pale veneer plywood wall lining gives the retail space a calm, continuous finish, with aligned panels and fine vertical joints visible across the shop wall.

Which plywood for shop counters and display units?

For shop counters and display units, choose sanded furniture plywood with a decorative veneer, melamine or HPL face for wear, cleaning and appearance. Counter fronts are visual surfaces; horizontal counter tops need a specified wear surface and supported edges; shelving needs a span and load design. One panel construction should not automatically be copied across all three positions.

A counter front may use a veneer that continues around a return. Mark the grain direction and the face selected for the return on the cutting drawing. A cashier-side work surface often benefits from a durable applied finish and edge detail because it sees repeated contact with bags, devices and cleaning cloths. Display shelves need an agreed support arrangement, including the location of brackets and any routed slots. A free-standing gondola must also be checked for stability and anchorage before its panel specification is finalised.

For a plywood display cabinet, the cabinet maker can use a better face on the public side and a practical back grade on concealed surfaces. This avoids treating every internal panel as a showroom face. A mirrored or illuminated cabinet makes edges and joints more visible, so agree edge banding and exposed plywood edges early. For display drawers, the accuracy of the panel cut and the hardware fixing positions usually matter more than the marketing name of the veneer.

Specify the load path for each unit. Merchandise weight moves through shelves, fixings, side panels, the base and finally the floor. Plywood can be part of that path, but the shopfitter must size the whole unit for its loads. Use cabinet-grade plywood when the project calls for precise visible cabinet components and melamine-faced plywood when the inside surfaces need a consistent factory finish.

A plywood retail counter combines a smooth front face, a matching worktop and clean exposed edges in a compact contemporary shop interior.

What fire rating for retail fit-outs should buyers request?

Request the fire classification required by the local authority for the actual wall lining or installed assembly, together with a test or classification report covering the specified build. Ordinary plywood has no universal retail fire rating. A reaction-to-fire result for one thickness, coating, mounting and substrate cannot be assumed for a different assembly.

Start with the building’s approved fire strategy, not a timber catalogue. In a shop, a display lining, a corridor wall, an exit route and a temporary exhibition structure can face different requirements. The project designer identifies the applicable code and the location of each finish. The procurement team then asks for the exact classification document and checks its field of application. The installer follows the tested fixing, backing and joint details where these affect the classification.

Fire reaction and fire resistance are different questions. Reaction-to-fire classifications describe how a product or assembly contributes to fire under a specified test regime. Fire-resistance ratings describe the ability of an element to retain functions such as integrity or insulation for a specified period. A decorative plywood panel sold for furniture is not automatically a fire-rated partition. Nor does an attractive coating make the entire wall compliant.

For an exhibition stand, obtain the organiser’s venue rules before purchasing. Some venues require documents for the exposed surface finish and may inspect samples or labels during build-up. A reusable display system benefits from keeping the fire documentation with the component schedule, so replacement panels are ordered to the same approved construction. The correct purchasing instruction is a named required classification, test evidence and matching installation detail, not a generic request for ‘fireproof plywood’.

Birch vs poplar for exhibition stands: which face works better?

Birch-faced plywood is the stronger visual choice for a crisp, pale timber look and visible edges, while poplar-faced plywood is a useful option for painted, lightweight-looking display designs. This comparison is about the face veneer and the specified panel construction, not an assumption that every birch-faced sheet has a birch core or that every poplar-faced sheet has a poplar core.

Selection point Birch-faced option Poplar or bleached-poplar face
Visible character Fine, relatively even grain with a clear-finish appearance Light, understated surface that accepts a restrained visual treatment
Typical design intent Exposed counters, premium-looking plinths, visible joinery Painted walls, light-coloured exhibition graphics, concealed cabinet parts
Edge appearance Depends on the actual inner veneer stack Depends on the actual inner veneer stack
Specification priority Match veneer figure and face grade across adjacent panels Match shade and preparation across the batch
Approval sample Finished face under venue lighting Primed or finished face under venue lighting

Truc Mai Plywood offers birch as an imported face veneer on a Vietnamese core, and also offers poplar and bleached-poplar faces. The core can be Styrax, Eucalyptus, Acacia or Pine, with combinations specified for the order. Compare like with like: hold thickness, core, surface preparation and finish constant before judging the visual difference. A heavier-looking exhibition feature is not necessarily made from a heavier core, and the face species alone cannot predict the finished sheet weight.

For a reusable stand, examine the edges after trial assembly. Repeated screw removal can damage any poorly designed fixing point. Inserts, mechanical connectors and replaceable edge pieces may suit a stand that travels between venues. A display that is assembled only once may justify a simpler fixing detail. See birch-faced plywood and engineered veneer panels for other face options before signing off the visual sample.

How should a shopfitter choose panel thickness and sheet format?

Use the fixture drawing to set thickness, then choose a stock sheet that minimises cutting and handling. Truc Mai’s normal range covers 3–40 mm, with standard formats of 1220 × 2440 mm, 1220 × 2280 mm and 1250 × 2500 mm. A wall lining and a load-bearing shelf should have separate thickness decisions even when the designer wants the same visible veneer.

Fixture component First design question Specification decision
Flat wall lining What backing and fixing centres support the sheet? Thickness, screw positions and joint spacing
Counter front Is the face flat, curved or routed? Surface quality, core construction and edge treatment
Counter top What wear, cleaning and support are expected? Face system, support layout and edge protection
Display shelf What load and unsupported span apply? Thickness and support calculation
Tall display side Where are hinges, brackets and connectors fixed? Core quality, machining and reinforcement
Exhibition plinth How will it be carried and assembled? Weight, cut list and connector access

The drawing must settle how each part is supported. A thick shelf with poor supports may perform worse than a thinner shelf with a properly designed rail. Similarly, a tall side panel needs a stable base and suitable anchorage. For a wall lining, the contractor should establish the position of services, fire-stopping details and the wall substrate before routing holes. Mark the reference edge so the CNC shop and installer use the same datum.

Sheet format matters when a shop programme repeats the same parts across many locations. A designer can arrange shelves and fronts to reduce seams or use the shorter format where its length suits the cut list. The choice also affects grain direction. A long, narrow piece cut along the face grain will not look the same as the same piece rotated to save material. Decide which visual requirement has priority before nesting the drawing.

Which face finishes survive daily retail handling?

HPL-faced plywood is a practical choice for high-contact counters, while melamine-faced panels suit consistent interior cabinet surfaces and veneer faces suit decorative exposed timber. The finish is chosen by use position, cleaning regime and desired appearance. A polished display plinth, a stockroom counter and a jewellery cabinet interior do not experience the same wear.

A laminate can protect the broad face, yet the edge remains an important part of the specification. Ask whether the edge will be banded, capped, painted or intentionally left as visible plywood. At a counter corner, a carefully detailed radius or protective edge can reduce chipping from repeated contact. Where a laminated panel meets a sink, drinks station or cleaning area, the designer should detail the joint and exposed core so water is not left sitting against unprotected wood.

For natural veneer, select the finished sample, not just the raw sheet. The final colour changes with coating, light and grain. A single showroom sample should include the face, edge and a representative joint. For a painted wall, specify sanding and primer compatibility rather than paying for a decorative grain that will be hidden. HPL-faced panels and melamine-faced plywood show the two factory-faced routes available for interior fittings.

What core construction gives clean routed edges and reliable fixings?

A well-joined furniture-grade veneer core gives the CNC operator a more consistent edge and a better basis for planned hardware fixing. Specify core grade and joining method alongside the face. Truc Mai’s furniture/interior construction uses an A-grade stitched core and sanded faces; commercial panels use a different core and preparation suited to less visible applications.

Look at a sample cross-section before approving routed profiles. Voids can become visible as dark gaps in a painted edge or undermine a narrow slot. Where the display design exposes plywood laminations, ask for an edge sample cut with the same tool path and finishing sequence. A photograph of the broad face alone cannot show whether the edge will meet the design intent.

Core stitching is a manufacturing step that holds veneer pieces together across and along the sheet. It helps maintain the lay-up during pressing and gives the mill a more orderly assembly. In Truc Mai’s standard practice, the outer core plies are usually stitched, with further stitching available by specification. The buyer should describe the machining requirement rather than simply demand the most elaborate construction for every concealed panel.

A screw fixed close to a narrow edge behaves differently from one placed into a broad face. Trial the intended screw, pilot hole and insertion method on the chosen panel. Where a fixture will be dismantled frequently, specify suitable inserts or other repeatable mechanical connections. Record the hardware type on the component drawing; a panel purchase order alone cannot resolve a connector problem.

How do you plan a plywood rack for shop merchandise?

Start a plywood rack for shop merchandise with the product weight, shelf span and anti-tip design, then work back to panel and hardware specifications. A rack holding boxed goods, hanging accessories or sample books has different loading patterns. The floor connection and the way customers pull products from the display also matter.

Map the heaviest intended load to its actual position. A uniformly distributed load and a concentrated load at the shelf front produce different bending and fixing demands. Identify whether the rack is freestanding, wall-attached or part of a larger gondola. The structural designer or shopfitting engineer should select supports, bracing and fixings appropriate to that arrangement.

Retail fixtures are repeatedly handled. A shelf may be loaded by staff, leaned on by a shopper and moved during a seasonal changeover. Protective front edges and replaceable fittings can make maintenance easier. In a modular rack, standardise hole positions and hardware references before production; otherwise nominally interchangeable panels may not align during a later rollout.

How should slatwall, pegboard and display rails be detailed?

Slatwall and pegboard fixtures need a purpose-designed slot or hole layout and a verified fixing system; ordinary flat plywood becomes a display support only after the assembly has been designed for its intended hardware and loads. A grooved sheet, a drilled panel and a proprietary metal rail system are not interchangeable simply because each holds hooks.

Specify hole diameter, spacing, edge clearance and rail position on a dimensioned drawing. The supplier should see the hardware sample or a reliable hardware specification. If a hook exerts force at the front face, the panel needs adequate backing and connection to the structure. For heavy merchandise, load should be carried by an engineered rail or support system rather than assumed to be safe because the plywood is thick.

Grooves remove material. A deep groove in a thin panel can leave too little section at the back, particularly if the panel has local core defects. Route a sample and inspect the remaining material before releasing the production run. If the design uses metal inserts, specify the insert and machining dimensions together. A good-looking routed groove is not evidence that a hook-and-panel assembly has the required capacity.

Consider the replacement strategy. A damaged modular slatwall section is easier to replace when the panel width, hole pitch, finish and fixing points are standardised. Label each part and keep the installation drawing with the project file. This is particularly useful when a chain refreshes displays without rebuilding the underlying wall.

How are shop panels cut, nested and labelled at the mill?

Mill cutting works from an approved cut list showing the source sheet, part dimensions, grain direction and labels. Truc Mai offers cut-to-size panels, including halves, thirds, quarters and six-part layouts, with the exact sizes agreed against the buyer’s drawing. Cutting is a manufacturing operation, not an instruction to the installer to improvise dimensions on site.

For example, a standard sheet can be divided lengthwise into 610 × 2440 mm halves, into 1200 × 800 mm pieces for a suitable layout, or into 1220 × 610 mm quarters. The saw kerf, trimming allowance and grain orientation must be considered before the cutting plan is approved. These examples describe layout choices rather than a promise that every combination nests without waste.

Send a component schedule with an unambiguous identifier for each part. The schedule should distinguish finished dimensions from rough-cut dimensions. If the edge will be banded later, identify whether the banding allowance is included. Mark which face is outward and whether mirrored parts are required. The cut-to-size plywood panels page explains how the mill option fits into a purchasing programme.

How do you check dimensions and surface quality before dispatch?

Check thickness, length, width, face grade, edge quality and pack identity against the written order and the approved sample. A retail fit-out is unforgiving of dimensional drift because repeated parts must align at joints, doors and display rails. Inspection should concentrate on the features that the finished fixture will expose.

For Truc Mai’s sanded and calibrated furniture panels, the quoted thickness tolerance can be ±0.3 mm; other constructions are specified to their appropriate tolerance. Length and width are quoted at ±2 mm. These are mill specifications, separate from any general tolerances in a national standard. A buyer ordering cabinet parts should identify whether the dimension applies to the full sheet or the finished cut component.

Inspect faces under oblique light for sanding lines, patches, veneer variation and handling marks. Inspect the edge after a representative saw cut for visible gaps. For an HPL or melamine face, inspect the laminate and the corners as well as the substrate. Where two panels meet in a visible sequence, place them together to judge colour and grain matching. A sample approved in isolation may not reveal an obvious mismatch across a long counter front.

The inspection record should follow the component schedule. Note any accepted appearance variations on the sample or specification rather than inventing a grade meaning after delivery. Face and back grades are quoted as a pair, and their appearance is agreed against the approved sample. This gives both buyer and mill a concrete basis for assessing the finished parts.

Which emissions documents matter for US and European interiors?

For US hardwood plywood with veneer core, ask for the TSCA Title VI certification and product scope; for EU furniture and wood-based articles, specify the applicable formaldehyde requirement and supporting test evidence. Bond strength, face grade and formaldehyde emissions are separate properties. A decorative surface finish does not replace an emissions file.

Under 40 CFR Part 770, the US formaldehyde limit for hardwood plywood with veneer core is 0.05 ppm under the specified test framework. Truc Mai’s CARB Phase 2 and TSCA Title VI third-party certification covers veneer-core hardwood plywood from 3–25 mm, certificate CARB/EPA 26053, mill ICTT-26053 and TPC-43. Buyers can compare the proposed panel thickness and construction with that scope before adding it to a US fixture schedule. The US formaldehyde limits page gives the relevant product distinctions.

The European Commission’s formaldehyde restriction sets 0.062 mg/m³ for furniture and wood-based articles under the REACH restriction. Its chamber conditions are not the same as a US ppm test, so a project file should retain the actual test method and article configuration. Ask the project team to identify the applicable finished-article requirement in the procurement schedule.

A panel may be ordered with UF adhesive at E0 emission under the mill’s stated specification. This describes an adhesive choice and an emissions designation, not a fire classification or a bond durability class. When the project requires a particular test method, write it on the order rather than relying on a shorthand label. Keep the certificate and test record with the material schedule used by the installer.

What moisture and adhesive specification suits a shop interior?

A dry, conditioned retail interior normally calls for an interior panel construction and a finish that suits the cleaning and humidity regime. Moisture-prone positions need a separately specified adhesive and edge-protection detail. The correct choice follows the exposure of the installed fixture, not the fact that it is inside a shop.

The USDA Forest Products Laboratory’s Wood Handbook chapter on adhesives describes urea-formaldehyde adhesive as widely used for interior panels and relatively less resistant to wetting. The same source distinguishes the greater wet-condition resistance of melamine and phenolic systems. The adhesive family does not by itself assign an EN bond class to a finished plywood construction.

A counter near a drinks preparation area, a shopfront display subject to condensation and a dry wall behind clothing racks have different exposure conditions. Detail the vulnerable edges and penetrations, including fastener holes and cable cut-outs. Coating the face while leaving a freshly cut edge untreated can create an avoidable weak point. Where cleaning agents are used, the finish supplier should approve the cleaning protocol for that finish.

Do not confuse moisture resistance with outdoor suitability. Retail furniture plywood and commercial interior panels are specified for their actual service environment. A display that will be installed in an open-air location requires a different product assessment and a project-specific exposure design. For indoor installations, the practical questions are where water may collect, how quickly surfaces dry and whether the joints can be maintained.

How many shopfitting sheets fit into a 40HC container?

The 40HC planning table below gives sheet counts, pack counts, panel volume and estimated panel mass for the listed core and thickness combinations. These are model outputs for panels only, using a 28,000 kg planning payload, nominal densities and packs about 1,000 mm high. Carrier and route limits, packing materials and actual sheet weights govern the final loading plan.

Core Thickness (mm) Sheet (mm) Packs Sheets/pack Sheets Volume (m³) kg/sheet Total kg Weight capped
Styrax 12 1220x2440 18 83 1494 53.4 17.9 26680 No
Acacia 12 1220x2440 16 83 1328 47.4 20.7 27510 No
Eucalyptus 12 1220x2440 15 80 1200 42.9 23.2 27860 Yes
Styrax 15 1220x2440 18 66 1188 53.0 22.3 26520 No
Acacia 15 1220x2440 16 66 1056 47.2 25.9 27350 No
Eucalyptus 15 1220x2440 15 64 960 42.9 29.0 27860 Yes
Styrax 18 1220x2440 18 55 990 53.0 26.8 26520 No
Acacia 18 1220x2440 16 55 880 47.2 31.1 27350 No
Eucalyptus 18 1220x2440 15 53 795 42.6 34.8 27690 Yes
Styrax 21 1220x2440 18 47 846 52.9 31.3 26440 No
Acacia 21 1220x2440 16 47 752 47.0 36.3 27270 No
Eucalyptus 21 1220x2440 15 45 675 42.2 40.6 27430 Yes

The model basis is: 18 packs for Styrax, 16 for Acacia and 15 for Eucalyptus; nominal densities of 500, 580 and 650 kg/m³ respectively; sheets per pack are derived from the pack-height limit and capped by the payload calculation. The table preserves the supplied model values rather than turning them into dispatch records. Actual packing weight is added when the forwarder and loading team prepare the shipment.

For a shop rollout, sheet count alone is not enough. A container may carry several face finishes, thicknesses and cut-component packs. The packing plan should show each specification separately, with the number of packs, the part labels and the loading sequence. A mixed shipment is often more useful than filling the container with a single panel that the project will not consume evenly. The container volume by thickness explanation covers the relationship between core density and available volume.

Plan the arrival around the installation sequence. Panels for a pilot store may be needed before the main rollout, while spare parts may be packed separately for later replacement. Ask the shipping team to identify the pack dimensions and total gross cargo weight on the final packing list. A spreadsheet based only on geometric sheet volume misses the handling and weight constraints that determine the actual load.

How should a buyer compare shopfitting plywood quotations?

Compare quotations against one construction schedule: application, core, adhesive and emissions, face, dimensions, finish, packing and quantity. Two offers called ‘shopfitting plywood’ can represent different products. A cheaper-looking line may omit the decorative face preparation or the labelled cutting operation that the installation programme requires.

Start with the component family. Separate wall lining, counters, cabinet carcasses and shelves instead of asking one grade to do everything. Specify the visible face and back, the core joining method and the exact finished thickness. Add the finish and edge detail, then the cut list. Finally state the inspection sample, required documents, packing and destination. The plywood RFQ checklist provides a useful order for these fields.

A sample should reproduce the proposed construction. An attractive veneer sample on a different core cannot show the routed edge or fixing behaviour of the ordered panel. Ask for a face-and-edge sample, and where necessary a cut component with the intended finish. Truc Mai offers samples; ordering plywood samples explains the process. Keep the approved sample reference on the purchase order.

What origin and chain-of-custody files should EU buyers request?

Request the species and origin records for the core and face veneer, the applicable chain-of-custody documents and the geolocation information needed for the EU importer’s due-diligence process. Decorative face veneer may originate in a different country from the core wood, so one generic ‘country of origin’ statement is not enough to describe the material supply chain.

The European Commission’s EUDR update states the application dates of 30 December 2026 for large and medium operators and certain smaller operators, and 30 June 2027 for other micro and small operators. The due-diligence file for plywood should identify relevant wood species and production plots. Truc Mai supplies origin records and geolocation files for both core and face veneer to support the importer’s file. See the face veneer origin files explanation for how those two material streams are documented.

Truc Mai holds FSC chain-of-custody certification, licence FSC-C196493 and certificate SA-COC-014545, with FSC 100% claims for eligible products. The sales and shipping documents identify the claim for the applicable product. The FSC licence verification page explains how buyers check a licence and the corresponding product claim. An order for certified material should record the claim in the commercial specification.

EU sourcing checklist showing core and face origin records, plot geolocation, harvest permits, forest-product lists, import declarations and FSC chain-of-custody certification.

How do you organise delivery for a multi-store fit-out?

Organise delivery around approved samples, component revisions, labelled packs and the store installation sequence. The commercial shipment is only one stage: the buyer also needs a reliable way to distribute the right components to the right fitting crew without reopening every pallet.

Truc Mai’s standard minimum order is one 40HC, with production typically 15–45 days after the deposit under the agreed order terms. Shipping can be arranged FOB Hai Phong, CFR or CIF. For a phased programme, group components by store or assembly family before finalising the packing schedule. A container that is easy to unload can still be difficult to distribute if labels do not correspond to the site drawings.

Before dispatch, check that the packing list identifies panel specifications, pack quantities and any component groups. The usual shipment file includes a commercial invoice, packing list and bill of lading, with the origin, inspection and other agreed documents. The shipment documents page lists the file set buyers normally coordinate with their freight team.

A plywood shipment checklist covering the commercial invoice, packing list, bill of lading, certificate of origin, phytosanitary and fumigation papers, and CIF insurance.

What should go on the final shopfitting panel specification?

The final specification should name every panel family, its use position and the exact construction and finish to be supplied. A procurement-ready schedule is more useful than a general request for ‘good plywood’. It gives the mill, CNC shop, freight team and installer a common description of the product.

  1. Identify the application. State whether the part is a wall lining, counter front, shelf, cabinet side or exhibition component, and identify any special loading or fire-design requirements.
  2. Set the core and adhesive. Name the agreed veneer core construction, joining method, glue system and emissions specification, with test documents where required.
  3. Approve the face. State face and back grades as a pair, the veneer species or factory-facing material, grain direction and finish sample reference.
  4. Fix dimensions. Record nominal sheet size, finished part dimensions, thickness tolerance, cut-list revision and edge preparation.
  5. Define packing. Specify component labels, grouping, protection of finished faces and the sequence needed at the installation site.
  6. Close the order file. Record quantities, shipment terms, required certificates, inspection reference and destination port.

For a plywood shop display programme, this schedule should be attached to the quotation request and carried through to the purchase order. If a shop counter has an HPL face but a matching veneer side, they belong on separate lines even when they share a core. A component drawing should also show which side faces the customer and which edge will be visible after assembly.

Send the approved drawings, component schedule and destination details with the enquiry. That gives the mill enough information to quote the right construction and to prepare a sample that reflects the finished retail fixture, rather than a generic plywood sheet.

The final panel brief covers part use, core and glue, paired face and back grades, dimensions and edge preparation, plus component labels and installation sequence.

Send your specification to contact@trucmaiplywood.com or through the quotation form.

Questions buyers ask

Can plywood be used behind a shop display?

Yes. A dry interior plywood lining can provide a practical backing for fixtures when the supporting wall, fixings and fire design are specified together.

Can I paint a plywood retail wall?

Yes. Choose a sanded, paint-ready face, seal exposed edges and test the primer and finish on a representative sample.

Is a clear lacquer suitable for display cabinetry?

A clear finish works well where the face veneer is selected for its visible grain. Agree the face and back grades against a sample before production.

Can a display unit combine different plywood finishes?

Yes. A shopfitter can specify a decorative face for customer-facing surfaces and a different finish for concealed panels, provided the construction schedule identifies each component.

What should a shopfitter send for a cut-to-size order?

Send the source sheet size, a dimensioned cut list, grain direction, edge-finish requirements, labels and quantities for each part.

Are white melamine faces suitable for shelf interiors?

White melamine-faced plywood is useful for wipe-clean interior surfaces. The shelf span and fixing arrangement should be checked against the intended load.

How is face veneer grade agreed?

Agree the visible face and back as a pair using an approved sample, then record the pair on the purchase specification.

Can plywood display parts arrive labelled?

Yes. Mill-cut parts can be grouped and labelled to a buyer-supplied component schedule to simplify sorting during installation.

What paperwork accompanies imported plywood?

The normal shipment file includes the invoice, packing list, bill of lading and the origin and test documents specified for the order.

Can several display-panel specifications share one container?

Yes. A mixed container can carry multiple agreed products, with pack dimensions, weights and part labels planned for each line.

Next step

Ask for a sample of your build

Send core, face, size and quantity. Free samples go out for the build you plan to order.

Request a quotation